Melun, Notre-Dame-de-l'Assomption

MELUN-ND

Building Data for Melun, Notre-Dame-de-l'Assomption

  •  
  • Type: Collegiate
  • Affiliation: Benedictine
  •  
  • Region: Ile-de-France
  • Department: Seine-et-Marne
  • Coords: 48.535, 2.6603
  •  
  • Surveyed: 1992-98

Map

Timeline and building units for Melun, Notre-Dame-de-l'Assomption A 'building unit' is an arbitrary unit of work based on bulk billing techniques used by quantity surveyors. 
    	    The unit is small enough to provide realistic figures in the small churches without becoming too huge in the large. 
    	    Six units would pay for one small vaulted bay in an aisle about 3 metres square, or a small first-floor gallery. 
    	    Such a bay would consist of an external wall with a small window, half of two columns about 3 meters tall, the floor and footings under them and the vault and roof overhead.
X

A 'building unit' is an arbitrary unit of work based on bulk billing techniques used by quantity surveyors. The unit is small enough to provide realistic figures in the small churches without becoming too huge in the large. Six units would pay for one small vaulted bay in an aisle about 3 metres square, or a small first-floor gallery. Such a bay would consist of an external wall with a small window, half of two columns about 3 meters tall, the floor and footings under them and the vault and roof overhead.

info

gray gray 240
1140
gray 90
1160
45
1170
24
1180
gray
1050 1140s 1160s 1170s 1180s 1250

Phases for Melun, Notre-Dame-de-l'Assomption The building sequence is based on my on-site analysis of the construction history,  
    	    using the techniques developed on the cathedral of Chartres called toichology, and described in a number of publications.
    	    The analysis of some of the smaller churches are more approximate than I would like, and need further analysis. 
    	    <p>I have used 'phase' rather than 'campaign' to to identify a contiguous zone with similar elements. 
    	    A campaign would be defined by recognisable breaks and construction joints in the fabric: there may be a number of phases within a campaign.
    	    One benefit is that separate programs by subcontractors, such as carvers, may be isolated, which is particularly useful in complex sections, such as portals.
    	    <p>Every phase has been assigned to a decade, so there may be more than one phase in a decade. 
    	    <p>While this is certainly imperfect, it will allow us to explore all the data, including costs, across time. 
    	    This is an on-going process, so as the data continues to be analyzed, the chronology and costing analysis will be further refined, and the synopsis updated. 
    	    <p>Clicking on any of the decade graphics will display all buildings that had work being done during that decade.
X

The building sequence is based on my on-site analysis of the construction history, using the techniques developed on the cathedral of Chartres called toichology, and described in a number of publications. The analysis of some of the smaller churches are more approximate than I would like, and need further analysis.

I have used 'phase' rather than 'campaign' to to identify a contiguous zone with similar elements. A campaign would be defined by recognisable breaks and construction joints in the fabric: there may be a number of phases within a campaign. One benefit is that separate programs by subcontractors, such as carvers, may be isolated, which is particularly useful in complex sections, such as portals.

Every phase has been assigned to a decade, so there may be more than one phase in a decade.

While this is certainly imperfect, it will allow us to explore all the data, including costs, across time. This is an on-going process, so as the data continues to be analyzed, the chronology and costing analysis will be further refined, and the synopsis updated.

Clicking on any of the decade graphics will display all buildings that had work being done during that decade.

1140

Phase 1 - 1140 - east (a) - 120 Units


Apse, transept footings and bases
1140

Phase 2 - 1140 - tower - 15 Units


Tower I
1140

Phase 3 - 1140 [1143] - east (c) - 105 Units


Apse and crossing clerestory
1160

Phase 4 - 1160 - nave (a) - 70 Units


Nave aisles
1160

Phase 5 - 1160 - tower II - 20 Units


Tower II
1170

Phase 6 - 1170 - nave (c) - 45 Units


Nave clerestory
1180

Phase 7 - 1180 - tower III - 24 Units


Tower III